POWER: 300VA
Insulation systems: 105/130/155/180 degree are available.
Primary is specified, 100/110/115/120/220/230/240/380/415V.
Secondary is specified by customer.
Design to meet UL/CSA/TUV/VDE/CE and other safety requirements.
ROHS 2.0 Directive and (SVHC/REACH) are conformity.
Application field: Telecomm. Power Supply
AC power supply transformer is the device installed in a power supply for voltage conversion. The primary and secondary can be design according to customer's request. The range of frequecy can be design 45~500Hz. The common frequency is 50~60Hz, 47~63Hz, 45~70Hz, 20-75Hz. Power supply has high requirements on the transformer。It requests transformer is with high efficiency, small loss, Low interference resistance, small magnetic leakage, low temperature rise. Especially for the high level insulation.
Power Range: 10VA to 450VA (EI 41 ~ EI133.2)
Phase: Single
Input/Output: Customized
Insulation: up to 4kV (Hi-pot)
Sample Lead Time: 3~5 days
Production Lead Time:3 Weeks (Urgent order can be negotiated)
Quantity:No MOQ Require
Specification Table
Power | Regulation |
Temperature Rise |
Size(mm) | Power | Regulation |
Temperature Rise |
Size(mm) | |||||||
(VA) | (%) | ℃ | L | W | H | F/A×B | (VA) | (%) | ℃ | L | W | H | F/A×B | |
10VA | 18.0% | 60℃ | 50 | 34 | 44 | 61 | 120VA | 7.5% | 60℃ | 86.2 | 72 | 72 | 71×63 | |
15VA | 18.0% | 60℃ | 50 | 40 | 44 | 61 | 140VA | 6.8% | 60℃ | 86.2 | 79 | 72 | 71×70 | |
25VA | 16.0% | 60℃ | 59.5 | 44 | 50.5 | 70.5 | 160VA | 6.5% | 60℃ | 96 | 75 | 80.5 | 76×61 | |
30VA | 15.0% | 60℃ | 59.5 | 48.5 | 50.5 | 70.5 | 190VA | 6.4% | 60℃ | 96 | 82 | 80.5 | 76×68 | |
35VA | 13.0% | 60℃ | 59.5 | 54 | 50.5 | 70.5 | 220VA | 5.0% | 65℃ | 105 | 79 | 91 | 76×58 | |
40VA | 12.0% | 60℃ | 68.5 | 52 | 58.5 | 81.5 | 260VA | 4.8% | 65℃ | 105 | 89 | 91 | 76×68 | |
50VA | 11.0% | 60℃ | 68.5 | 58 | 58.5 | 81.5 | 290VA | 4.8% | 65℃ | 105 | 94 | 91 | 76×73 | |
60VA | 9.0% | 60℃ | 68.5 | 68 | 58.5 | 81.5 | 350VA | 4.6% | 65℃ | 114 | 94 | 97.5 | 95×80 | |
70VA | 8.0% | 60℃ | 78.5 | 62 | 68.5 | 90 | 420VA | 4.5% | 65℃ | 114 | 104 | 97.5 | 95×90 | |
90VA | 8.0% | 60℃ | 78.5 | 68 | 68.5 | 90 | 450VA | 4.5% | 65℃ | 114 | 109 | 97.5 | 95×95 |
EI Transformer Main Materials (IQC process)
All the material is inspected strictly with ISO9001:2015 quality program.
Core: appearance inspection and core loss test.
Copper wire: pinhole test and coat of adhesion test
EI Transformer Process
EI Transformer Testing Items